160
MW MHI 501F
GAS TURBINE GENERATOR
(For sale Must buy both)
These units are new and for sale as a pair. They
were purchased for roughly $80 million for both.
We are direct with the owners and all reasonable offers will
be considered. Spare parts included. More
details available on request.
Nominal
Base Case Natural Gas 163.27 MW Gross at 84.7 °F (29.3°C)
CIT, and 14.678 psia (1.012 bar a)
Generator Voltage: 16,500 V, 3,600 rpm, 60 Hz.
Power Factor 85%.
Industrial for Simple Cycle Power Application
Dual fuel:
Natural Gas is a primary project fuel. Distillate is a
secondary fuel
Natural Gas Lower Heating Value: 11,600 kcal/kg (20,880
Btu/lb)
Distillate Oil Lower Heating Value: 10,100 kcal/kg (18,180
Btu/lb)
Fuel Temperature
Range:
Distillate: 80°F (27°C)
Natural Gas: +74.3°F to 392°F (23.5°C to 200°C)
{MHI expects natural gas at a temperature no lower than 23.5
°C (74.3 °F)}
Type of enclosure: Thermal & sound for outdoor installation. Presence of high salt concentration in the atmosphere must be incorporated into design.
Dry Low NOx Combustion System
Starting Device: 1,850 kW Electric Motor
NOX Control
Diluent
Distillate: Water
Natural Gas: Dry
Quality of
Injection Water NO x Control-- Demin water (supplied by P)
Contaminant Quantity
Total Dissolved Solids 0.025 mg/l
SiO2 (as such) 0.01 mg/l
Lube Oil System:
Power Source: Shaft Driven Main Pump 100% Capacity
· Coolers: Plate & Frame
· Filters Duplex
· Coolant: Closed cycle cooling water loop
Cool Side - Max. 122°F (50°C)
Closed Cycle
Cooling Water Quality - Conditioned water (supplied by P)
Contaminant Quantity
Total Dissolved Solids 0.025 mg/l
SiO2 (as such) 0.01 mg/l
Fire Protection: High pressure CO2 bottle type
Inlet System
Scope:
· Ductwork
· Inlet filters
· Evaporative cooler and mist eliminator
· Silencers as needed to comply with the Purchase Contract
Exhaust System
Scope:
· Exhaust Expansion Joints
· Bypass Stack (Option)
· Exhaust System Transition
· Exhaust Orientation: Axial
Cleaning System:
Q Water System: semiautomatic on-line/off-line (manual local
control)
Ratings and Performance
Rating [NG]
[Distillate]
Ambient Temp,°F(°C) 74.3 (23.5) 74.3 (23.5)
Ambient Relative Humidity (%) 78 78
Ambient Press, psia (bar a) 14.678 (1.012) 14.678 (1.012)
CIT, °F (°C) 74.3 (23.5) 74.3 (23.5)
Generator Gross Output, kW 169,420 147,850
Gross Heat Rate,
Btu/kWh (kJ/kW) (LHV) 9,438 (9,958) 10,243 (10,807)
Total Aux, Loads (kW) 900 1,250
Exhaust Pressure Losses,
in. (mm) H2O 5.9 (150)
The equipment package is as follows:
Combustion Turbine Enclosure
Combustion Turbine Longitudinal
Electrical and Control Packages
Evaporative Cooling Media and System
Exhaust Ductwork
Fin Tube Cooler (Air Radiator)
Gas and Oil control Valves
Generator and Exciter
Generator Rotor Removal Dolly
Inlet and Inlet Filters and Silencers
Lube Oil Cooler and Supports
Prefabricated Piping (Local)
Starting Package
Turbine Cooling Air Coolers
Turbine Performance Information
Simple Cycle Heat Rate (LHV): 9,491 btu/kwh at Average Conditions
Simple Cycle Output: 162,370 kw at Normal High Conditions
Average Dry Bulb Temp: 23.5 Deg. C
Average Relative Humidity: 78.0%
Normal High Dry Bulb Temp: 29.3 Deg. C
Normal Relative Humidity: 58%
Extreme High Dry Bulb Temp: 44 Deg. C
Normal Low Bulb Temp: 20 Deg. C
Extreme Low Bulb Temp: 9.0 Deg. C
Mean Annual Rainfall: 1,083 mm
Natural Gas Pressure @ Inlet: 36 (±1%) barg minimum
Spare Parts Package for each 501F
Baskets
Transition Pieces
Transition Seals
Cross Flame Tubes
Fuel Nozzles (DLN, Dual)
Row 1 Blades
Row 1 Vanes
Row 1 Segment
Turbine Journal Bearings
Re-newables/Consumables Combustion Inspection
Re-newables/Consumables Major Inspection