5.6 MW Engine Generator Complete Operating Plant
3 Superior 16-SGTA Spark Ignited natural gas Recip.
Available Immediately

$800,000 (as is where is)

The plant prime movers are 3 – Superior 16-SGTA spark ignited natural gas reciprocating engines. These are 16 cylinder 13,200 cubic-inch turbocharged units rated at 1875 kW each. They operate at 900 rpm. The units were built in 1986 by Cooper/Superior in Ohio, they were setup to operate on landfill gas and ran on the factory test stand for four hours. After delivery the project was cancelled and they were placed in storage.

The plant can also be broken up into three individual plants of 1875 kW each. The switch gear, mufflers, radiators and all other associated equipment is easily individualized.

The units were built in 1986 by Cooper/Superior in Ohio, they were setup to operate on landfill gas and ran on the factory test stand for four hours. After delivery the project was cancelled and they were placed in storage.

In 1993 these units were shipped to Syracuse and installed in there current location. They currently are set up to operate on natural gas and located in a 25,000-sq. ft. building.

The units are currently shutdown but can be started up and operated at any time. We are still connected to the local utility and can produce full power into the grid at any time. Currently due to the deregulation power prices are so low it is not economically viable to operate the plant.

The plant can also be broken up into three individual plants of 1875 kW each. The switch gear, mufflers, radiators and all other associated equipment is easily individualized.

The engines alone are approx. 19 feet long 8 feet wide and 10 feet high. The engines dry weigh approx. 56,000 lbs. The skidded units (engine and generators) weigh approx. 96,000 lbs.

The entire Gen-set and engine unit is approx. 30 feet long 8 feet wide and 12 feet high.

In 1993 they were shipped to there present location, installed and converted to operate on natural gas.

Each of the units have CB-13 turbochargers that were purchased in 1993 new from Cooper as part of the conversion to natural gas operations. We also have 3 ET-13 turbos. One of these is fully functional and used as a spare unit. The others are in need of repair.

The units were started on July 26,1993 and operated until September 15, 1997.

The nearest parts supplier and service is Cooper Energy Services in Mount Vernon Ohio. There are several other suppliers and service companies around the country.

Following are the hours on each unit when they were overhauled and their current hours.

#1. 23,336 27,931

#2 19,532 30,041

#3 24,000 26,747

In Feb. of 97 unit #1 had a new crank installed, line bore, new bearings, Oct of 96 new pistons, liners and Oct. 95 rebuilt heads heads.

In March of 96 unit #2 was rebuilt

April 96 unit lower end rebuilt and March 97 heads rebuilt

Equipment list

Radiator’s

Three SmithCo Model #1F28-100-2 Serial #86B-210

Generators – Manufactured by Kayto - Synchronous 4160 volts

#1 Serial #92998-01 Model #237560000

#2 Serial #92998-02 Model #237560000

#3 Serial #92998-03 Model #237560000

All three generators were inspected, cleaned, and the main bearings replaced by Kayto in 1996

Catalyst

There is one catalyst, it was installed in 1994

Switch gear

Delta Controls Serial # 11321-01

Volts 4160

Amps 1200

Mufflers

3 hospital grade silencers

Air filters

Cycoil Manufactured by: American Air Filter Co.

Model #1F28-100-2

Battery charger with battery bank

48 volt DC system for control power

Air compressors

Ingersoll Rand 20 HP two stage

#1 Hours 18,944 Model # TPTA 40 Serial # 30T566612

#2 Hours 5,773 Model # TPTA 40 Serial # 30T566007

Air storage tanks

Two 1,000 gallon – 200 psi rated pressure tanks

Oil storage tanks

One 2,000 gallon new oil tank

One 1,500 gallon used oil tank

One spill containment tank for both of the above tanks to sit in.

Oil transfer pump system

System designed to remove used oil from the engines and pump it into the used oil tank and then pump new oil from the tank into the engines.

Transformers

Main transformer 4,160 Volt to 34,500 Volt Serial # SEA 7099-0101

Impedance 7.07

Full load KVA 5000/5600 OA 6250/7000 FA

55/65 C temp rise

Manufactured May 1993

Other transformers

One 4,160 Volt to 480 Volt

One 480 Volt to 208 Volt

 

Waste heat boiler

4,000,000 BTU/HR exhaust heat to hot water recovery unit installed in 1996

Oil filters

There are two Allen filter units for each engine and three Purifier TF1000 bypass 2micron filter units on each engine.

Remote Transmitting Unit

Manufactured by Valmet for communications with the local utility.

Direct Transfer Trip Unit

Series 6710

RX GR-3

48 VDC

Contact Milt Fyre for more details.
Phone: 503-239-5157 Fax: 503-239-5136