The Utility Warehouse

Power Plant Equipment to be Used with 2 GE Frame 9E (50Hz.) Turbine Generators.

Auxiliary Boiler, Circulating Water Pumps, 120/160 MVA Transformer

All units are new and with manufacturers warranty.  Manufactured 1997.  Stored by or in accordance with manufacturers recommendations.



Auxiliary Boiler Asking price US$ 850,000

Specification

Quantity : 1Unit

Boiler Capacity (Saturated Steam) : 9442 kg/hr ( Use to Deaeretor)

Boiler Capacity (Super Heated ) : 46900 kg/hr

Steam Condition : Operating Pressure : 23.44Barg
                           Operating Temp. 265.1 Deg C.

Fuels : Natural Gas or No. 2 Oil

Electric Power : 120V AC / 50Hz/ 1PH ( for Burner Management Cabinet)
               415V AC / 50Hz (for Boiler Feedwater Pump and Fuel Oil Pump)

Scope of Supply

Basic Boiler and trim

Low-Nox Burner system for firing natural gas or No. 2 oil

Fuel piping train designed for mounting at the burner front

Burner management system

Combustion and feedwater controls

Deaerator and Feedwater pump system with interconnecting piping

Interconnecting ductwork

Blow Down Tank

Stack mounted on support steel extending 35M above base line

Light oil pump set

F.D. fan, motor drive and silencer

Air flow measuring device

Non-return valve & steam stop valves with spool piece

50 mandays at the jobsite for supervision of installation, start up and commissioning.

 

Circulating Water Pumps Asking price US$ 560,000

Specification

Quantity : 3sets

Type : Vertical

Low Water Level : 3500mm

Normal Water Level : 4110mm

Distance from top of concrete of pump chamber to bottom of pump chamber : 4720mm

Manufacturer : Torishima (Japan)

Fluid Specific Gravity : 1.0

Capacity : Q : 12721m3/h, H : 22.25m

Motor Capacity : 980kw

Motor Manufacturer : GEC Alstom

Electric Power : 6600 AC / 50Hz

Scope of Supply

Vertical wet pit Circulating water pumps with accessories

Electric motor drivers

Coupling and safety guards

One Complete set of consumable spare parts per pump for use in preparation for commercial operation

 

Transformer (Hyundai Heavy Industries Co., Ltd. ) Asking price US$ 3,300,000

Generator Step-up TR : 2Sets

Rated Voltage : 15kv delta / 241.5kv Y Grounded

MVA Rating : 120 / 160MVA

Frequency : 50Hz

Impedance Range : 14%

Efficiencies at full load : 99.65%

Vector group : Ynd1

No load tap changer

230kv –115kv-22kv Auto Transformer : 1Set

Rating Voltage : 230kv / 115kv / 22kv

MVA Rating : 120MVA / 30MVA

Frequency : 50Hz

Percent Impedance :

H-X : 7%

H-Y : 6%

X-Y : 4%

Efficiencies at 120MVA : 99.72

ON Load Tap Changer

Vector Group : Ynaod1

Auxiliary Transformer : 2Sets

Rating Voltage : 15kv / 6.9kv

MVA Rating : 10MVA / 12.5MVA

Phase / Frequency : 3 / 50Hz

Tap voltage : 15.0kv ± 2x2.5%

Tap Change : On Load Tap Change

Connection : DYn1

 

CT, VT ( ABB(GEC ALSTOM)) Asking price US$ 330,000

230kv Current Transformer : 6Sets Ratio : 700 ~ 1500

230kv Current Transformer : 3Sets Ratio : 600 ~ 1200

115kv Current Transformer : 3Sets Ratio : MR800 / 4x5A

115kv Current Transformer : 3Sets Ratio : 1600 / 2x5A

  22kv Current Transformer : 9Sets Ratio : 600 ~ 1200 / 3x5A

  22kv Current Transformer : 3Sets Ratio : MR3000

230kv CCVT : 30Sets Ratio : 230kv / V3 / 115 ~ 66.4V

230kv CCVT : 9Sets Ratio : 230kv / V3 / 115 ~ 66.4V

115kv CCVT : 3Sets Ratio : 115kv / V3 / 115 ~ 66.4V

  22kv CCVT : 3Sets Ratio : 22kv / 2x110 ~ 66.4V

CEMS : 2 Sets Asking price US$ 250,000

Manufacturer : Columbia Scientific

Type : Time shared between Bypass and HRSG Stack

Sample Prove : 2 per Block

Analyzer : O2, CO2, NOx, So2

Data Acquisition System : One PC with Printer

Control Power : AC 220V, 50Hz

Analyzer Shelter : Analyzer Shelter to House all with Redundancy Air Conditioner

Contact Milt Fyre for more details.
Phone: 503-239-5157
Fax: 503-239-5136
milt@rmaglobal.com