Auxiliary Boiler Asking price US$ 850,000
Specification
Quantity : 1Unit
Boiler Capacity (Saturated Steam) : 9442 kg/hr ( Use to Deaeretor)
Boiler Capacity (Super Heated ) : 46900 kg/hr
Steam Condition : Operating Pressure : 23.44Barg
Operating Temp. 265.1 Deg C.Fuels : Natural Gas or No. 2 Oil
Electric Power : 120V AC / 50Hz/ 1PH ( for Burner Management Cabinet)
415V AC / 50Hz (for Boiler Feedwater Pump and Fuel Oil Pump)Scope of Supply
Basic Boiler and trim
Low-Nox Burner system for firing natural gas or No. 2 oil
Fuel piping train designed for mounting at the burner front
Burner management system
Combustion and feedwater controls
Deaerator and Feedwater pump system with interconnecting piping
Interconnecting ductwork
Blow Down Tank
Stack mounted on support steel extending 35M above base line
Light oil pump set
F.D. fan, motor drive and silencer
Air flow measuring device
Non-return valve & steam stop valves with spool piece
50 mandays at the jobsite for supervision of installation, start up and commissioning.
Circulating Water Pumps Asking price US$ 560,000
Specification
Quantity : 3sets
Type : Vertical
Low Water Level : 3500mm
Normal Water Level : 4110mm
Distance from top of concrete of pump chamber to bottom of pump chamber : 4720mm
Manufacturer : Torishima (Japan)
Fluid Specific Gravity : 1.0
Capacity : Q : 12721m3/h, H : 22.25m
Motor Capacity : 980kw
Motor Manufacturer : GEC Alstom
Electric Power : 6600 AC / 50Hz
Scope of Supply
Vertical wet pit Circulating water pumps with accessories
Electric motor drivers
Coupling and safety guards
One Complete set of consumable spare parts per pump for use in preparation for commercial operation
Transformer (Hyundai Heavy Industries Co., Ltd. ) Asking price US$ 3,300,000
Generator Step-up TR : 2Sets
Rated Voltage : 15kv delta / 241.5kv Y Grounded
MVA Rating : 120 / 160MVA
Frequency : 50Hz
Impedance Range : 14%
Efficiencies at full load : 99.65%
Vector group : Ynd1
No load tap changer
230kv –115kv-22kv Auto Transformer : 1Set
Rating Voltage : 230kv / 115kv / 22kv
MVA Rating : 120MVA / 30MVA
Frequency : 50Hz
Percent Impedance :
H-X : 7%
H-Y : 6%
X-Y : 4%
Efficiencies at 120MVA : 99.72
ON Load Tap Changer
Vector Group : Ynaod1
Auxiliary Transformer : 2Sets
Rating Voltage : 15kv / 6.9kv
MVA Rating : 10MVA / 12.5MVA
Phase / Frequency : 3 / 50Hz
Tap voltage : 15.0kv ± 2x2.5%
Tap Change : On Load Tap Change
Connection : DYn1
CT, VT ( ABB(GEC ALSTOM)) Asking price US$ 330,000
230kv Current Transformer : 6Sets Ratio : 700 ~ 1500
230kv Current Transformer : 3Sets Ratio : 600 ~ 1200
115kv Current Transformer : 3Sets Ratio : MR800 / 4x5A
115kv Current Transformer : 3Sets Ratio : 1600 / 2x5A
22kv Current Transformer : 9Sets Ratio : 600 ~ 1200 / 3x5A
22kv Current Transformer : 3Sets Ratio : MR3000
230kv CCVT : 30Sets Ratio : 230kv / V3 / 115 ~ 66.4V
230kv CCVT : 9Sets Ratio : 230kv / V3 / 115 ~ 66.4V
115kv CCVT : 3Sets Ratio : 115kv / V3 / 115 ~ 66.4V
22kv CCVT : 3Sets Ratio : 22kv / 2x110 ~ 66.4V
CEMS : 2 Sets Asking price US$ 250,000
Manufacturer : Columbia Scientific
Type : Time shared between Bypass and HRSG Stack
Sample Prove : 2 per Block
Analyzer : O2, CO2, NOx, So2
Data Acquisition System : One PC with Printer
Control Power : AC 220V, 50Hz
Analyzer Shelter : Analyzer Shelter to House all with Redundancy Air Conditioner