| GE MS5001N Gas Turbine
with the following features |
NEW
|
REFURBISHED
TO 0 HOURS
|
-
Simple cycle, single shaft 2 bearings
heavy duty type gas turbine and axial compressor
|
|
X
|
-
Fabricated structural basement, supporting
the gas turbine, alternator and its own auxiliaries, the air inlet and
exhaust gas plenum
|
|
X
|
-
Base mounted junction boxes
|
|
X
|
-
Starting system with Diesel
|
|
X
|
-
Integral mounted gauge board installed
in control room, installed on turbine frame skid, with indication of the
main turbine pressure parameters
|
|
X
|
-
Vibration detector seismic type
|
|
X
|
-
Thermocouples for measuring the gas turbine
critical temperatures
|
|
X
|
-
Header and nozzles for compressor cleaning
|
|
X
|
-
Load coupling between the speed reduction
gear and alternator
|
|
X
|
|
|
X
|
|
-
Closed forced-feed lube oil system common
for the gas turbine and driven equipment, complete with:
|
|
|
-
carbon steel, internally epoxy painted,
lube oil tank located in the gas turbine base
|
|
X
|
|
|
| |
X
|
1.1 ACOUSTICAL ENCLOSURE
Acoustical Enclosure, suitable for outdoor installation, is to be
anchored on the unit baseplat, no foundation is required.
The enclosure, supplied with loose walls and roof, to be erected
at site, is provided to assure acoustical abatement and thermal separation
to the outside.
The expected average sound attenuation is 80 dB(A) pressure level
at one meter from the enclosure.
| The following equipment
and system are provided inside the enclosure: |
NEW
|
REFURBISHED
TO 0 HOURS
|
| |
|
|
-
Fire detection system with thermal type
detectors
|
X
|
|
-
CO2 fire extinguishing system
(piping and spray nozzles)
|
X
|
|
-
Internal A.C. and D.C. emergency lighting
|
X
|
|
-
Ventilation system complete with A.C.
motor driven fan (2x100%) and conveying duct
|
X
|
|
-
G.T. AIR INLET SYSTEM
| New gas Turbine Air Inlet
System is provided for an up and forward arrangement and consists of: |
NEW
|
REFURBISHED
TO 0 HOURS
|
| |
|
|
-
CS filters, CS weatherproof filters chamber
|
X
|
|
-
Blow-in door and relevant instrumentation
|
X
|
|
-
Air inlet duct (carbon steel) from the
filter chamber to the gas turbine inlet plenum, including a 2,5 m (baffles)
silencer
|
X
|
|
-
C. S. supporting structure
|
X
|
|
1.3 EXHAUST GAS SYSTEM
| New vertical turbine exhaust
gas system |
NEW
|
REFURBISHED
TO 0 HOURS
|
| |
|
|
|
|
X
|
|
|
|
X
|
|
|
|
X
|
|
|
|
X
|
|
-
Drain from exhaust hood to water trap
|
X
|
|
1.4 SPEED REDUCTION GEAR
The Speed Reduction Gear, located between the turbine
and the generator, is coupled to the G.T. exhaust plenum, with 5100 /3000
rpm ratio, and provided with the following auxiliary facilities:
-
Seismic type vibration detector, located on the gear
case and connected with the G.T. monitoring and protection system
-
Bearing embedded RTD's for the bearings temperature
control
1.5 ELECTRICAL GENERATOR
The electrical generator is a Synchronous
machine, ventilated in open air-circuit, with the following characteristics:
-
Manufacturer, Alsthom
-
Nominal Voltage 8,4 kV
-
Frequency 50Hz
-
Power factor (cos.Æ
) 0,8
-
Cooling air and stator windings RTD's
and relevant terminal junction boxes
-
Bearing embedded RTD's for bearings temperature
control
-
Seismic vibration type detectors connected
with the gas turbine monitoring and protection system
-
Brushless excitation type with the necessary
equipment suitable for the excitation control
-
Ventilation fans on the generator shaft
ends
-
M.V. section with Current and Potential
transformers (CT's & PT's) for metering and protection and Surge arrestors
and lightning protection
-
Neutral isolated to the ground
1.6 CONTROL AND L.V. SYSTEM
The control and L.V. equipment consist of:
-
MARK V G.T. control board
-
Generator Control and Protection board
-
Generator Excitation control Board complete with Automatic
Voltage Regulator (A.V.R.)
-
Fire and Gas detection system Control board
-
Motor Control Centre for the G.T. unit auxiliaries including
the dry type transformer for the unit lighting system
-
New battery Charger and D.C. distribution panel
-
New battery arranged on rack, and installed in the battery
room, separated from the L.V. boards room
1.8. NEW MISCELLANY
-
Foundation bolts and plates
-
Packing
-
Firefighting means bottles for the fire extinguishing
system to be installed outside the package, adjacent to the unit
-
Interconnecting piping between the Gas Turbine Generating
Unit and its Auxiliary skids
-
Instruction manuals for maintenance and operation (four
copies)
Limits of supply
Electrical:
-
Generator terminal bars (8,4 kV)
-
Control panels terminals input/output
Mechanical:
-
Fuel inlet flange
-
Oil lubrication duct flange
Note: The units will be completely
renewed by replacement of the hot gas path and each part which it may need.
The refurbished turbogenerator shall have the same guarantee as per a new
unit (8000 firings hrs or 18 months from shipment).
The units can be uprated to duplex fuel, adding the
gas fuel system as per your request, performances enhancement kits as well.
The field activities and civil works are not included
and can be provided upon request.
Contact Milt Fyre for more details.