17 MW Alstom Steam Turbine Generator Sets
3 complete sets for sale

Model
T167-215,  Output 17 MW @ 5.5kV,  50Hz.  Condensing 
3,000rpm,  Inlet Pressure  40bar,    Inlet Temperature  465ēC
(Click here for images)

Contact Lane Kadel, 503-595-5418 or lane@rmaglobal.com 

General Specifications

   



 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alstom  Model: T167-215,  Output 17 MW @ 5.5Kv,  50Hz.,  3,000rpm,  Inlet Pressure  40bar,    Inlet Temperature  465ēC,   Condenser Pressure  0.072bar Tem 40ēC,  M.C.R   78 TPH, Max 857 PIH, 0.35bar requirement,   0.35 bar = 108ēC (gauge pressure),    Number 1 Heater  2bar (a) = 121ēC 3.38 Tonnes,   
Number 2 Heater  
7bar (a) = 165ēC 3.08 Tonnes,   Condenser    59 TPH,   Y02 Heater   100ēC.

QUANTITY
Total: 3 TURBINES and accessories as listed below.

Unit Detail

 

Unit 1

Unit 2

Unit 3

Commission Date

Jan 1966

Sept 1969

Dec 1969

ID Number

3299

3353

3354

Run Hours

71,000

47,000

46,000

Stops - 72 hrs or more

32

28

36

Number of starts after 72 hrs

115

168

173

 

Plant Sizes and Weights

 

Weight (tonnes)

Size (mm)

Alternators

 

 

ˇ1 Stator

32.5

6500 x 2700 x 2500

ˇ2 Rotor

10.0

550 diam. x 6100

Turbine

 

 

ˇ3 Top Casing

12.5

5000 x 3600 x 2000

ˇ4 Bottom Casing

20.0

5600 x 3600 x 2000

ˇ5 Rotor

5.0

2000 diam x 6000

ˇ6 Condenser

31.0

6400 x 3400 x 5100

ˇ7 Tanks

6.5

3000 x 3900 x 7000

 

This equipment is presently stored at two separate sites.


SIite I.
The three turbine impellers, housings, alternators and rotors are stored in containers and on container flats in a secured warehouse.   They are stored under plastic tents in both a thermostatically and humidity controlled atmosphere.
 

Site II.
The three condensers, tanks, pumps, de-aerators and other ancillary equipment (outlined below) are stored in a secured depot with the majority of the equipment being containerized.

Container TPHU 645664 7
8 6 Extraction pumps
9 6 Extraction pump motors
10 6 Extraction pump suction chambers
11 3 spare extraction pump spindles
12 3 sight glasses and pipe work (probably oil tank)
13 3 + 3 Valve chest cover panels
14 4 spare rear alternator bearings
15 1 front alternator bearings - spare
16 1 Extraction pump impeller - spare

Container MLCU 229977 0
1 Numbers 2, 3 and 4 turbine governor - oil pump housing (front hydraulic unit pedestal)
2 3 turbine cylinder covers
3 Numbers 2, 3 and 4 alternator bearing housing
4 Numbers 2, 3 and 4 governor control linkages

Container MLCU 212380 0
1 Numbers 2, 3 and 4 Excitation units (complete)
2 3 turbine cylinder covers
3 Drum of new spare condenser tube erosion shields
4 2 drums assorted spares
5 3 AC oil pumps
6 1 DC oil pump
7 1 spare oil pump


Container GSTU 416747 6
1 Numbers 2, 3 and 4 main steam inlet control valves
2 2 control valve hand wheels
3 2 condenser CW valves
4 2 half drums of spares

Container XTRU 201486 5
1 3 turbine base plates
2 6 turbine side plates
3 3 alternator base plates
4 Turbine cylinder covers

Container GSTU 460832 9
1 Turbine base and front plates
2 Various steam and water valves
3 Hydraulic pipe work
4 3 hydraulic turbine control units with covers
5 3 steam spray control valves
6 2 constant head chambers
7 10 condenser expansion joints OD 780mm, ID 590mm

Container XTRU 211329 8
1 12 condenser plates (bases for springs)
2 3 oil cooler change over valves
3 3 drains cooler (??) units
4 60 condenser spring
5 6 oil coolers
6 1 water/water cooler
7 2 oil tank sight glasses

Container GSTU 414760 7
1 Condenser tubes
2 1 electric feed pump on bed - with motor
3 3 water/air cooler units and inlet and outlet caps

Container ITLU 653024 5
1 1 feed pump on bed - no motor
2 1 turbo feed pump unit on bed
3 1 electric feed pump with motor on bed
4 1 electric motor for feed pump
5 1 water/air cooler unit
6 Condenser tubes




Test Results - Final Rotor Results 

Rotor

Date

Temperature ēC

IR at 0.5 kV (megohms)

PI

 

 

Air

Winding

Actual

Corrected to 40ēC

 

 

 

 

 

1 min

10 min

1 min

10 min

 

 

1/11/01

 

 

 

 

 

 

 

T4

 

25

37

3500

15000

3150

13500

4.28

T2

 

25

37

16000

40000

14400

36000

2.50

T3

 

25

37

6000

17000

5400

15300

2.80

 Test Results - Final Stator Results 

Stator

Date

Temperature ēC

IR at 2.5 kV (megohms)

PI

 

 

Air

Winding

Actual

Corrected to 40ēC

 

 

 

 

 

1 min

10 min

1 min

10 min

 

No10

9/11/01

23

24

 

 

 

 

 

L1

 

 

 

3250

9000

2435.5

6750

2.77

L2

 

 

 

3000

7500

2250

5625

2.50

L3

 

 

 

3300

9000

2475

6750

2.73

 

 

 

 

 

 

 

 

 

No 12

9/11/01

23

31

 

 

 

 

 

L1

 

 

 

3750

9000

2250

5400

2.40

L2

 

 

 

3750

9500

2250

5700

2.53

L3

 

 

 

3900

9000

2340

5400

2.31

 

 

 

 

 

 

 

 

 

No 11

16/11/01

24

47

 

 

 

 

 

L1

 

 

 

1100

4000

1650

6000

3.63

L2

 

 

 

1050

3750

1575

5625

3.57

L3

 

 

 

1250

4000

1875

6000

3.20

 

Contact Lane Kadel, 503-595-5418 or lane@rmaglobal.com  



Email: sales@rmaglobal.com   Phone: (503) 595-5418   Fax: (503) 635-0091   Copyright 1995-2008: RMA Inc.