750kW Solar Saturn (10) Gas Turbine Generator Set
(2 Units Available)
50Hz. Liquid Fuel.
Contact Milt Fyre for more details.
Phone: 503-239-5157 milt@rmaglobal.com

MODEL                                           :              GSC 1200

SERIAL NO.                                    :              S 429xxx

ENGINE DETAILS

ENGINE                                          :              SOLAR GAS TURBINE

MODEL                                           :              SATURN 10

VERSION                                        :              t 1210

I.D.H.                                               :              1011240-00

SERIAL NO.                                    :              30xxx

H.P.                                                  :              1115

R.P.M.                                             :              22143

 

GENERATOR DETAILS

GENERATOR                                 :              SIEMENS

TYPE                                               :              IFC 3 316 B3

SERIAL NO.                                    :              165019

PHASE                                            :              3

VOLT                                               :              415

FREQUENCY                                 :              50 HZ

R.P.M                                              :              1500

K.V.A.                                               :              750

AMPERE                                         :              1040

POWER FACTOR                          :              0.8

 

ENGINE COMPONENTS

COMPRESSOR                             :              8 STAGE, AXIAL FLOW

TURBINE                                        :              3 STAGE, AXIAL FLOW

COMUSTIAN CHAMBER              :              THROUGH-FLOW, ANNULAR

REDUCTION GEAR ASSLY          :              PLANETRY TYPE REDUCTION

STANDARD                                    :              FIRST STAGE 22300 TO 6000 RPM

SECOND STAGE                           :              6000 TO 1500 RPM ENGINE SYSTEM

AIR SYSTEMS                                :              AIR FLOW THROUGH SCREENED INLET DUCT, EXHAUST FROM COLLECTOR. COMPRESSOR BLEED AIR COOLS TURBINE ROTOR, PRESSURISES OIL SEALS AND

                                                                        OPERATES COMPRESSOR 6 STAGE

                                                                        BLEED VALVE

ENGINE STARTING SYSTEM     :              PENUMATIC

LUBRICATION SYSTEM              :              CLOSED CIRCUIT, VENTED OIL

                                                                        SYSTEM INCLUDING OIL TANK,

            PRESSURE PUMPS, OIL FILTER,

            PRESSURE SWITCHES, OIL COOLER                 ETC., OIL TANK CAPACITY - 75

            GALLONS, FILTERATION TO 10 –

            MICRON PARTICLE SIZE

OIL USED                                       :              SYNTHESIZED HYDROCARBON OIL

FUEL                                               :              hsd liquid fuel

strainer                                      :              40 mesh screen

 

Contact Milt Fyre for more details.
Phone: 503-239-5157
Fax: 503-239-5136
Email:milt@rmaglobal.com


Email: sales@rmaglobal.com   Phone: (503) 239-5157   Fax: (503) 239-5136   Copyright 1995-2005: RMA Inc.