10.3 MW Avon Gas Turbine Generator Set
For Sale 60Hz. 1534-1012L / 10 Avon Maxis Liquid Fuel.
Complete Package Mounted on Trailers.
Contact Milt Fyre milt@rmaglobal.com 503-351-9898
Each generating set consists of and Avon-powered gas turbine driving A/C generator and exciter through a speed reducing gearbox supplying 10.3 mw base, 16 mw peak (depending on ambient temperature) at 13.8 KV. 60 Hz and is designed for starting without and external A/C supply.
The complete installation is mounted on a main and auxiliary trailer designed for transporting all the necessary equipment by road to any site where it is desired to provide and additional or emergency mains power supply. The plant controls are located in a control room at the front of the auxiliary trailer.
The gas turbine is a liquid fueled Rolls-Royce Avon maxi type 1533-10LL.
For starting the gas turbine is rotated by a 120V D/C motor enclosed within the intake hub fairing. The starter drive incorporates a self-engaging ratchet mechanism.
The power turbine is a single stage unit driven by Avon gas generator exhaust gases.
Power turbine is a single exhaust gases pass through an exhaust duct and silencer to and exhaust stack which discharges the gases to the atmosphere. A splitter type silencer reduces exhaust noise to an acceptable level.
The speed-reducing gearbox is driven by the power turbine through a shaft with flexible couplings. The gear is suitable for full continuous running and can withstand 10% overloads for abort periods. It uses single helical, inviolate gear supported by plain white metal bearings.
The A/C generator is a horizontal salient pole, brushless machine. Excitation is by a revolving armature brushless generator complete with rotation rectifiers and a plot exciter integral with the main exciter. The generator is totally enclosed and cooled by a closed air system. The gas turbine is a fuel-controlled engine, so that the constant conditions of load and ambient atmospheric qualities, engine speed is directly related to the amount of fuel supplied to the gas generator. A Change load requires a related change in fuel supplied to maintain a constant output system and constant A/C frequency the system embodies and electronic governor unit, which monitors critical performance qualities.
Gas Generator Description: Rolls Royce gas generator
| Type: |
1534-1012L / 10 |
| Base Load: | 10.3 MW |
| Peak Load (depending on Tem,p: | 16 MW |
| Date Manufactured: | MARCH 1977 |
| Date Fist Put Into Service: | 21 SEPT 1978 |
| Manufacturers No: | 38201 |
| Hours Run Since New: | 25,308 Hrs |
| Number of Starts: |
1671 |
| Hours Run Since Overhauled: |
1249 Hrs |
| Number of Starts Since Overhauled: | 74 |
Fuel: Liquid (Distillate)
Power Turbine: EAS 1 free vortex
Type: Single stage
Nominal Speed: 6500 ver/minGearbox:
GEC Marine and industrial Gear Ltd.
Type: HSG28WH
Ser. No: H3012311
Input Speed (max Speed): 6450r/mim
Output Speed (max Speed): 1800 r/mim
Normal Speed: 1400 r/min
Max Output Torque: 82235NM
Lubricating Oil pressure: 2.8 bars (~ 40 psl)
Single Reduction Type
Speed Ratio: 6500/1800
A/C Generator:
GEC Generator Ltd.
Silent Pole excitation
Kilowatts 14.4 KV
Rating: 10.3 MW
Volts: 13.8 KV+/- 5%
Phase: 3
Frequency: 60 Hz @1800 rpm
Coolant: Air
M/CF Coolant Temperature: 15 deg CExcitation System:
GEC Turbine generator Ltd. A/C generator w/permanent magnet pilotExcitation volts: 66v
Date of Manufacture: 1978Datum Conditions:
Air Inlet Temp: 50 deg C
Ambient Pressure: 1013 Mill-BarsFuel Supply system comprising a fuel forwarding package and piping to the Avon Fuel System.
Lubrication system comprising a gas generator external oil supply system and an oil supply for the power turbine, gearbox and A/C generator.
Electrical equipment cubicle and fuel control system.
Air Filtration equipment.
Noise attenuation equipment, supply by Cullum Detunners Ltd.
Main and auxiliary trailers supplied by King Truck Equipment Ltd.
Main and auxiliary tractors.
Weigh labels are fixed to each trailer indication the weight of the trailers and tractors.
Weight of each trailer and tractor:
Main Trailer Weight - rear (Road Transport Conditions): 132.5 Tons
Six (6) axle hydraulic elevation c/w power pack 48 wheels
Aux Trailer weight - front (Road Transport Conditions): 36.2 Tons
Maintenance Historical Background:
12 march 1988:
Gas generator received in for investigation into breather / sump pressure compressor out -let casing and tower shaft housing checked. But results were negative. Generator re-assembled and tested breather/sump pressure found to be 0.2 HG and accepted.
30 march 1988:
Avon 4102 oil pump drive shaft fitted
8 July 1988:
Generator received in and stripped, repairs carried out to make serviceable. Generator re-assembled and tested in accordance with R/R overhaul manuals and test procedures. Note: inspection and test certificated dated 7 July 1988 attached
6 November 1989:
Gas generator received in the following turbine blade failure, generator stripped , cleaned and inspected . Repairs and replacement items carried out and fitted where required. R.T.C overhaul to zero hour's life. Generator reassembled, balanced, and tested all in accordance with R/R overhaul manuals and test procedures. Release for further service C.O # 4552 Note: certificate of inspection dated Nov. 6 1988, July 5 , 1990, July 11 ,1990 attached.
15 June 1991:
Time run since reconditioned 1249 hours Number of starts 74 Time run since new 1249 hours .