33MW GE Frame 6B Cogen Power Plant for Sale

60Hz. Natural Gas.  Deltak heat recovery steam generator.

 Steam capacity 280Klbsm/hr @ 410psig/640F

Contact Milt Fyre    milt@rmaglobal.com  503-351-9898

 

1. EQUIPMENT OVERVIEW
The equipment being made available for purchase is a GE MS6001B Gas Turbine 33 MW Power Generation Package with Deltak heat recovery steam generator. Steam capacity is nominally 280Klbsm/hr @ 410psig/640F. For detailed equipment information reference Table 2.

2. EQUIPMENT STATUS
The cogeneration facility was operating satisfactorily when it was shutdown in February of 2004 by the equipment operator. The equipment was idled when a new power facility was brought on-line.
Equipment preparations for a long-term outage were made by the cogeneration facility operator and the details of the equipment preparation are not known. It appears that minimal preparation was performed to preserve the equipment. Some equipment was removed and placed in climate controlled storage such as motors and switchgear. Prospective buyers should perform due diligence and/or assume some maintenance will be required prior to returning equipment to service.

3. EQUIPMENT CONDITION
The following information is offered in good faith; however, OWNER DOES NOT MAKE ANY REPRESENTATION OR WARRANTY, EXPRESSED OR IMPLIED, AS TO THE CONDITION OF THE EQUIPMENT, AND SPECIFICALLY MAKES NO REPRESENTATION OR WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE. A prospective purchaser of the equipment must conduct its own due diligence as to the condition of the equipment. The equipment will only be made available for purchase on an “AS IS, WHERE IS” basis.
Visual inspections and electrical / mechanical test were performed on the major components of the cogeneration facility in March 2009. The inspections and tests were performed to provide a reasonable assessment of the current condition of the equipment. The equipment assessment summary is provided in 

 

 

Table 1 and equipment details are provided in Table 2.

 

Table 1: Summary of Equipment Conditions Equipment

Condition

  1. Salvage

  2. Poor 

  3. Fair

  4. Good

  5. Excellent

Last Maintenance

      Approx. Hours Since Last Maintenance

Gas Turbine

Fair

Dec. 2001

Major Inspection:

o Combustion hardware replaced
o
Turbine nozzles cleaned & inspected
o
VIGV’s; cleaned & inspected, replaced inner bushings
o Compressor stationary blades cleaned, inspected and hand dressed
o
Case bolting replaced

Refurbished Rotor:
o
Separated rotor
o
Compressor wheels un-stacked blades removed cleaned, inspected and hand dressed
o
Replaced turbine buckets
o
Balanced compressor
o
Balanced turbine
o
Replaced through bolts
o
Balanced rotor assembly

10,700

Generator

Fair

Nov. 1996

Major Inspection:
o
Removed field
o
Cleaned, baked & varnished field
o
Installed new 18Mn18Cr field retaining rings
o
At speed balanced field
o
cleaned and painted stator
o
Partial re-wedge of stator
o
Installed flux probe
o
Testing and assembly performed under directive of GE Generator Specialist

43,300

Load Gear

Fair

Nov. 2000

Major Inspection:
o
Disassembled NDT gears
o
Installed new quill shafts
o Bearings replaced
o
Labyrinth oil seals replaced

14,000

Accessory Gear

Fair

Nov. 2000

Major Inspection:
o
Disassembled and changed gears
o
Bearings replaced
o
Labyrinth oil seals replaced

14,000

Generator Accessory

Fair

Nov. 1996

o Switch gear cleaned and tested per GE directive
o
Wiring inspected & tested
o
Rat guard on GAC grouted

43,300

Diesel Starter

Fair

Nov. 2000

o Changed lube oil & filters
o
Changed fuel filters
o
Inspected torque converter

14,000

Boiler

Fair

Nov. 2000

o State Inspection
o
Repaired boiler liner, (new skin)

14,000

Filtration System

Poor

Nov. 2000

o Repaired holes in filter housing roof
o
Cleaned & painted filter housing
o
Replaced filter elements (turbine & generator)

14,000

Lube Oil System

Good

Nov. 2000

o Replace main pump rotors and bearings
o
Inspected and lubed auxiliary pump
o
Replaced lube oil filters

14,000

Hydraulic System

Good

Nov. 2000

o Replaced main pump
o Inspected and lubed auxiliary pump
o
Replaced hydraulic oil filters
o
System check

14,000

Control System

GE-Mark IV

Poor

Dec. 2001

o Tested and adjusted per directive of GE Control Specialist
o
Control curve adjusted for changes associated with up-grade hardware and VIGV 86 degree opening

10,700

Table 1 LEGEND for Condition:

  1. Salvage - parts and/or scrap.
  2. Poor - significant repair and/or component replacement.
  3. Fair - clean, inspect and perform normal maintenance.
  4. Good - clean and inspect no repair.
  5. Excellent - new or recently refurbished.

 

 

Table 2: Equipment Summary

Driver

Comments

Description

Frame 6B Gas Turbine

Circa 1985

Manufacturer

General Electric

Manufactured

Schenectady, NY

Model

MS-6001-B

Serial Number

282522

Air Inlet Temperature

93F

Altitude

16 feet

Fuel

Natural Gas

Power

3330kw

Turbine Exhaust

1028F

RPM

5,100

Compressor Stages

17

Power Turbine Stages

3

NOx Emissions Control

Steam Injection / 75ppm

NP

169487

Fired Hours

~100,000

10,720 Since Major

Total Fired Starts

~100

Reduction Gear

Comments

Description

5105/3600 RPM @ 49,700kw

Manufacturer

General Electric

Manufactured

Lynn, Mass.

Model

S-644A4

Serial Number

273824

 

Description

Air cooled generator

Manufacturer

General Electric

Manufactured

Lynn, Mass.

Model

6A2

Serial Number

335X441

NP

169377

Stator Max. Temp.

130C

Field Max. Temp.

145C

Performance Condition

Rated

Peak

KVA

48,824

51,556

Stator Amps

2,043

2,157

Stator Volts

13,800

13,800

Field Amps

386

390

Excitation Volts

250

250

Power Factor

0.85

0.90

RPM

3,600

3,600

Starter/Helper

Comments

Description

Diesel Engine Starter

Manufacturer

Detroit Diesel Allison

Manufactured

Detroit, Michigan

Model

V-71 / 7123-7300

Serial Number

12VA-077270

Description

Hydraulic Torque Converter

Manufacturer

Twin Disc, Inc.

Model

4-SGE-2015-1

Serial Number

282852

Auxiliary Equipment

Comments

Generator Isolation

Open Air

Generator Excitation

Brushless

Control Cabinet

Mark IV Speedtronic

Lube Oil System

GE; moved filters external and added larger heat exchanger to reduce oil temperature.

See attached photo

Over-speed Protection

Woodward Pro-Tech 203

Electronic Redundant System

External Cooling

Added external fin-fan exchanger and pumps

Inlet Filtration

Donaldson TTDOO-9027

Comp. Wash System

RMC

See attached photos

GE Accessory Gearbox

Type - ABJAS6A550 650HP/5100RPM/3583RPM/1415RPM

S/N-273733 Lynn, Mass., see attached photos

HRSG Flame Detection System

HRSG H2O Analyzer

Conductivity & Sodium

HRSG Exhaust Analyzer

ABB; stack emissions, oxygen, NOX & CO

 

Description

Steam Drum and Boiler

Manufacturer

Deltak Corporation

Manufactured

1984

Surface Area

142,700 Sq. Ft.

Serial Number

8318

MAWP

500psig

Steam Temperature

640F

Steam Capacity

325klbm/hr

Description

Economizer

Replaced S/N 8318 in 1993

Manufacturer

Deltak Corporation

Manufactured

1993

Surface Area

75,995 Sq. Ft.

Serial Number

S93117-1669

MAWP

550psig

Description

Superheater

Manufacturer

Deltak Corporation

Manufactured

1984

Surface Area

4,027 Sq. Ft.

Serial Number

8318

MAWP

500psig

Steam Capacity

325klbm/hr

 

More Images Available on Request

 

 

 

 

Contact Milt Fyre    milt@rmaglobal.com

Email: sales@rmaglobal.com   Phone: (503) 595-5418   Fax: (503) 635-0091   Copyright 1995-2010: RMA Inc.