33MW GE Frame 6B Cogen Power Plant for Sale
60Hz. Natural Gas. Deltak heat recovery steam generator.
Steam capacity 280Klbsm/hr @ 410psig/640F
1. EQUIPMENT OVERVIEW
The equipment being made available for purchase is a GE MS6001B Gas Turbine 33
MW Power Generation Package with Deltak heat recovery steam generator. Steam
capacity is nominally 280Klbsm/hr @ 410psig/640F. For detailed equipment
information reference Table 2.
2. EQUIPMENT STATUS
The cogeneration facility was operating satisfactorily when it was shutdown in
February of 2004 by the equipment operator. The equipment was idled when a new
power facility was brought on-line.
Equipment preparations for a long-term outage were made by the cogeneration
facility operator and the details of the equipment preparation are not known. It
appears that minimal preparation was performed to preserve the equipment. Some
equipment was removed and placed in climate controlled storage such as motors
and switchgear. Prospective buyers should perform due diligence and/or assume
some maintenance will be required prior to returning equipment to service.
3. EQUIPMENT CONDITION
The following information is offered in good faith; however, OWNER DOES NOT MAKE
ANY REPRESENTATION OR WARRANTY, EXPRESSED OR IMPLIED, AS TO THE CONDITION OF THE
EQUIPMENT, AND SPECIFICALLY MAKES NO REPRESENTATION OR WARRANTY OF
MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE. A prospective purchaser
of the equipment must conduct its own due diligence as to the condition of the
equipment. The equipment will only be made available for purchase on an “AS
IS, WHERE IS” basis.
Visual inspections and electrical / mechanical test were performed on the major
components of the cogeneration facility in March 2009. The inspections and tests
were performed to provide a reasonable assessment of the current condition of
the equipment. The equipment assessment summary is provided in
Table 1 and equipment details are provided in Table 2.
|
Table 1: Summary of Equipment Conditions Equipment |
Condition Salvage Poor Fair Good Excellent |
Last Maintenance |
Approx. Hours Since Last Maintenance |
||
|
Gas Turbine |
Fair |
Dec. 2001 |
Major Inspection: o Combustion hardware replacedo Turbine nozzles cleaned & inspected o VIGV’s; cleaned & inspected, replaced inner bushings o Compressor stationary blades cleaned, inspected and hand dressed o Case bolting replaced Refurbished
Rotor: |
10,700 |
|
|
Generator |
Fair |
Nov. 1996 |
Major Inspection: o Removed field o Cleaned, baked & varnished field o Installed new 18Mn18Cr field retaining rings o At speed balanced field o cleaned and painted stator o Partial re-wedge of stator o Installed flux probe o Testing and assembly performed under directive of GE Generator Specialist |
43,300 |
|
|
Load Gear |
Fair |
Nov. 2000 |
Major Inspection: o Disassembled NDT gears o Installed new quill shafts o Bearings replaced o Labyrinth oil seals replaced |
14,000 |
|
|
Accessory Gear |
Fair |
Nov. 2000 |
Major Inspection: o Disassembled and changed gears o Bearings replaced o Labyrinth oil seals replaced |
14,000 |
|
|
Generator Accessory |
Fair |
Nov. 1996 |
o Switch gear cleaned and tested per GE directiveo Wiring inspected & tested o Rat guard on GAC grouted |
43,300 |
|
|
Diesel Starter |
Fair |
Nov. 2000 |
o Changed lube oil & filterso Changed fuel filters o Inspected torque converter |
14,000 |
|
|
Boiler |
Fair |
Nov. 2000 |
o State Inspectiono Repaired boiler liner, (new skin) |
14,000 |
|
|
Filtration System |
Poor |
Nov. 2000 |
o Repaired holes in filter housing roofo Cleaned & painted filter housing o Replaced filter elements (turbine & generator) |
14,000 |
|
|
Lube Oil System |
Good |
Nov. 2000 |
o Replace main pump rotors and bearingso Inspected and lubed auxiliary pump o Replaced lube oil filters |
14,000 |
|
Hydraulic System |
Good |
Nov. 2000 |
o Replaced main pumpo Inspected and lubed auxiliary pump o Replaced hydraulic oil filters o System check |
14,000 |
|
Control System GE-Mark IV |
Poor |
Dec. 2001 |
o Tested and adjusted per directive of GE Control Specialisto Control curve adjusted for changes associated with up-grade hardware and VIGV 86 degree opening |
10,700 |
Table 1 LEGEND for Condition:
- Salvage - parts and/or scrap.
- Poor - significant repair and/or component replacement.
- Fair - clean, inspect and perform normal maintenance.
- Good - clean and inspect no repair.
- Excellent - new or recently refurbished.
Table 2: Equipment Summary
|
Driver |
Comments |
||
|
Description |
Frame 6B Gas Turbine |
Circa 1985 |
|
|
Manufacturer |
General Electric |
||
|
Manufactured |
Schenectady, NY |
||
|
Model |
MS-6001-B |
||
|
Serial Number |
282522 |
||
|
Air Inlet Temperature |
93F |
||
|
Altitude |
16 feet |
||
|
Fuel |
Natural Gas |
||
|
Power |
3330kw |
||
|
Turbine Exhaust |
1028F |
||
|
RPM |
5,100 |
||
|
Compressor Stages |
17 |
||
|
Power Turbine Stages |
3 |
||
|
NOx Emissions Control |
Steam Injection / 75ppm |
||
|
NP |
169487 |
||
|
Fired Hours |
~100,000 |
10,720 Since Major |
|
|
Total Fired Starts |
~100 |
||
|
Reduction Gear |
Comments |
||
|
Description |
5105/3600 RPM @ 49,700kw |
||
|
Manufacturer |
General Electric |
||
|
Manufactured |
Lynn, Mass. |
||
|
Model |
S-644A4 |
||
|
Serial Number |
273824 |
||
|
Description |
Air cooled generator |
|||
|
Manufacturer |
General Electric |
|||
|
Manufactured |
Lynn, Mass. |
|||
|
Model |
6A2 |
|||
|
Serial Number |
335X441 |
|||
|
NP |
169377 |
|||
|
Stator Max. Temp. |
130C |
|||
|
Field Max. Temp. |
145C |
|||
|
Performance Condition |
Rated |
Peak |
||
|
KVA |
48,824 |
51,556 |
||
|
Stator Amps |
2,043 |
2,157 |
||
|
Stator Volts |
13,800 |
13,800 |
||
|
Field Amps |
386 |
390 |
||
|
Excitation Volts |
250 |
250 |
||
|
Power Factor |
0.85 |
0.90 |
||
|
RPM |
3,600 |
3,600 |
||
|
Starter/Helper |
Comments |
|||
|
Description |
Diesel Engine Starter |
|||
|
Manufacturer |
Detroit Diesel Allison |
|||
|
Manufactured |
Detroit, Michigan |
|||
|
Model |
V-71 / 7123-7300 |
|||
|
Serial Number |
12VA-077270 |
|||
|
Description |
Hydraulic Torque Converter |
|||
|
Manufacturer |
Twin Disc, Inc. |
|||
|
Model |
4-SGE-2015-1 |
|||
|
Serial Number |
282852 |
|||
|
Auxiliary Equipment |
Comments |
|||
|
Generator Isolation |
Open Air |
|||
|
Generator Excitation |
Brushless |
|||
|
Control Cabinet |
Mark IV Speedtronic |
|||
|
Lube Oil System |
GE; moved filters external and added larger heat exchanger to reduce oil temperature. |
See attached photo |
||
|
Over-speed Protection |
Woodward Pro-Tech 203 |
Electronic Redundant System |
||
|
External Cooling |
Added external fin-fan exchanger and pumps |
|||
|
Inlet Filtration |
Donaldson TTDOO-9027 |
|||
|
Comp. Wash System |
RMC |
See attached photos |
||
|
GE Accessory Gearbox |
Type - ABJAS6A550 650HP/5100RPM/3583RPM/1415RPM |
S/N-273733 Lynn, Mass., see attached photos |
||
|
HRSG Flame Detection System |
||||
|
HRSG H2O Analyzer |
Conductivity & Sodium |
|||
|
HRSG Exhaust Analyzer |
ABB; stack emissions, oxygen, NOX & CO |
|||
|
Description |
Steam Drum and Boiler |
||
|
Manufacturer |
Deltak Corporation |
||
|
Manufactured |
1984 |
||
|
Surface Area |
142,700 Sq. Ft. |
||
|
Serial Number |
8318 |
||
|
MAWP |
500psig |
||
|
Steam Temperature |
640F |
||
|
Steam Capacity |
325klbm/hr |
||
|
Description |
Economizer |
Replaced S/N 8318 in 1993 |
|
|
Manufacturer |
Deltak Corporation |
||
|
Manufactured |
1993 |
||
|
Surface Area |
75,995 Sq. Ft. |
||
|
Serial Number |
S93117-1669 |
||
|
MAWP |
550psig |
||
|
Description |
Superheater |
||
|
Manufacturer |
Deltak Corporation |
||
|
Manufactured |
1984 |
||
|
Surface Area |
4,027 Sq. Ft. |
||
|
Serial Number |
8318 |
||
|
MAWP |
500psig |
||
|
Steam Capacity |
325klbm/hr |
||
More Images Available on Request