SULZER UNITS DETAILS:

UNIT 8

UNIT 9

UNIT 10

UNIT 11

TYPE:

8TAF48

8TAF48

10TAF48

10TAF48

RPM:

250

250

250

250

BNP:

3250

3250

4400

4400

DATE OF ERECTION:

1971

1971

1974

1975

DATE OF DISMANTLING:

1983

1983

1983

1983

ACTUAL RUNNING HOURS:

19314

3913

21343

4724

% OF ACT-WORKING:

18.7%

3-8%

27-44%

6-8%

WEIGHT IN TONS:

100

85

70

70

HEIGHT:

3.80 METERS

3.80 METERS

3.80 METERS

3.80 METERS

BREADTH:

2.80 METERS

2.80 METERS

2.80 METERS

2.80 METERS

LENGTH:

11.60 METERS

9.80 METERS

8.00 METERS

8.00 METERS

SIEMENS GENERATORS:

 

 

 

 

WEIGHT IN TONS:

HEIGHT:

BREADTH:

LENGHT:

UNIT:

MOTORS: 35 TONS EACH.

5.60 METERS

5.20 METERS

5.20 METERS

4

ROTORS: 3 units-80 TONS EACH./1 unit-30 TONS

3.60 METERS

3.00 METERS

2.70 METERS

4

SULZER DIESEL ENGINES:

 

 

 

 

SR.NO.

5279512TAF48

52785100TAF48

526088TAF48

5260008TAF48

A.O.R.M.

999662060

-

55916180TAF48

40211960

6 H.P.

5280

4400

4400

3520

SIEMENS GENERATORS:

 

 

 

 

K.V.A.

4300

3940

2850

2850

C/S:

50

50

50

50

V

11000

11000

11000

11000

A.M.R.S.

226-3 phase/ SN.(D7320041601)

188-3 phase/ SN.(D7320041501)

188-3 phase/ SN.(D7320041501)

SR(6920030801)

 

·         DIESEL ENGINE

Description:

       1

 2

       3 & 4

1. MADE

SULZER

SULZER

SULZER

2. TYPE

5279512 T.A.F 48

5278510 T.A.F. 48

526808 T.A.F 48

3. R.P.M.

250

250

250

4. RATED OUT PUT

5280 BHP

4400 BHP

3520 BHP

1.   MADE

SIEMENS

SIEMENS

SIEMENS

2.   V.D.E

 

0530/69

0530/69

3.   TYPE

IDK 6166DE 12.Z1973

IDK 59196DE 12.Z1973

IDK 59196DE 12.Z1970

4.   PHASE

3 PH

3 PH

3 PH

5.   SERIAL NUMBER

D 7320041601

D 7320041501

D6920036802

6.   VOLTAGE

11000V

11000V

11000V

7.   AMP

226

118

149.5

8.   K.V.A.

4300

3580

2850

9.   C & F

0.8

0.8

0.8

10. R.P.M.

250

250

250

11. EXICITATION  VOLTAGE

115

130

102

12. AMP

260

293

252

13. INSULATION  CLASS

F/B1P11-B00

F/B1P11-B00

B-P11

14. AMBIENT TEM

52°C

52°C

52°C

15. FREQUENCY

50 C/F

50 C/F

50 C/F

Operating Hours

These Sulzer 4 units worked as substitution stations in peak time for  5  years   approximately 3  to 4 Hours per a day.

   Last overhaul

These Sulzer 4 units  has  been  out  of  service  in  its  excellent condition  because  of  regular  programmed maintenance ( defensive maintenance ) they  received during  service  as  per Aramco  Maintenance  System which  based  on operating hours.

 

 

 

 

 

 

·         UNIT 1

Part

Weight in Tons

Height in Meters

Breadth in Meters

Length in Meters

SULZER
ENGINE

100.00

3.80

2.80

11.60

SIEMENS 
GENERATOR

35.00

5.60

5.20

5.20

·          
UNIT 2                            

Part

Weight in Tons

Height in Meters

Breadth in Meters

Length in Meters

SULZER
ENGINE

85.00

3.80

2.80

9.80

SIEMENS  
GENERATOR

35.00

5.60

5.20

5.20

Part

Weight in Tons

Height in Meters

Breadth in Meters

Length in Meters

SULZER
ENGINE

70.00

3.80

2.80