5.2MW Solar Taurus T-60 Gas Turbine Generator Sets
for sale
3 Mobile (trailer-mounted) Sets and 7 Regular Sets
50/60Hz.
These are low hour mobile GTG sets in excellent condition.
Table 1. Performance Data ISO*, XQ5200 Mobile Power Unit
English Metric
Power Output 5,200 kWe 5,200 kWe
Heat Rate 11,263 Btu/Kwe-hr 11,900 kJ/Kwe-hr
Fuel Flow (LHV) 59.8 mmBTU/hr 59.8 mmBTU/hr
Emissions, NOX 25 PPMvd 25 PPMvd
5.84 LBM/Hr 2.65 kG/Hr
CO 50 PPM vd 50 PPM vd
7.1 LBM/Hr 7.1 LBM/Hr
Gen. Voltage 12.47or 13.8 kV 3.22 kG/Hr
Gen. Frequency 60 Hz 60 Hz
Voltage Steady State 0.5% 0.5%
Short Circuit 300% for 10 sec. 300% for 10 sec.
* ISO, Sea Level. 60% relative humidity, Natural Gas Fuel, No inlet or exhuast losses.
Table 2. Dimensional Data & Weights, Installed, XQ5200 Mobile Power Unit
English Metric
Length 48 ft. 14.6 meters
Width 21 ft. 6.4 meters
Height 26.6 ft. 8.1 meters
Installed Weights
Turbine Section 118,000 lbs 54 M tons
PCR Trailer 55,000 lbs 25 M tons
Table 3. Dimensional Data & Weights, Installed, XQ5200 Mobile Power Unit
English Metric
Natural Gas Fueled
Gas Pres. 250 PSIG 172 KPAG
Max. Gas Demand 1,400 SCFM 39.6 M3/Min
Foundation
Gravel Compacted to 2,500 lbs/ft2 120 kPA
Fuel Quality
Clean Dry Fuel Per Solar
Spec ES 9-98
BASIC PACKAGE: Solar T-60 ( B.O.M )
The Taurus 60 Industrial Power Generator (IPG) is a compact, rugged gas turbine generator set that has been designed to meet the requirements for industrial and utility power generation applications. The unit is provided as a completely integrated module ready for installation. The gas turbine engine, gearbox, generator, control system, fuel system, lubrication system, start system, and ancillary equipment needed for site operation on natural gas are included with each unit.
Each package includes a sound attenuated enclosure for the turbine generator and a PCR control building to house all generator and turbine control functions.
Approximate overall dimensions are: 32 feet, 0 inches (9753 mm) long 8 feet,
0 inches (2438 mm) wide.
Approximate height of package is 10 feet, 8 1/4 inches (3258 mm) and may vary
with ancillary equipment and generator selection. Four lifting gussets are
provided on each section.
Drip pans are welded beneath the package frame to collect potential liquid
spills. The drip pans also provide a tight seal for containment of fire
suppression agent for packages supplied with an enclosure.
Tube Fittings. All tube connections use compression fittings. Tubing and
fittings are 316 stainless steel. Piping. Package piping is designed and
fabricated to ANSI B31.3.
ELECTRICAL SYSTEM
The Taurus 60 IPG generator set is designed to comply with the requirements
of the National Electrical Code. Unless otherwise noted package motors and
heaters are rated for 460 VAC, 60 Hertz, 3 phase. Motor space heaters are
provided for motors over 5 hp (3.75 kW) and are rated for 120 VAC, 60 Hertz, 1
phase.
Fire Detection and Suppression System. The gas turbine enclosure will be
provided with ultra violet fire detectors and fire monitoring system. The fire
suppression system agent is C02. In the event of a fire being detected within
the unit, the unit will shutdown, the enclosure ventilator louvers will close,
and horns will sound. Gas Detection System. Gas detection monitors are provided
in the turbine enclosure. Upon detection of 20% LEL, alarms will sound. Upon
detection of 75% LEL, the unit will shut down and all louvers will open, and all
ventilator fans will activate.
GAS TURBINE ENGINE
The Taurus 60 gas turbine engine is a single shaft axial flow engine. The output
gearbox, including accessory drive pads, is a separate, close-coupled unit
located at the inlet end of the turbine. The engine assembly consists of: Gear
unit with accessory drive pads. Air inlet collector with flexible flange
connection. Axially split case in the vertical plane, eleven-stage axial flow
compressor with variable temperatures. Geometry control on inlet guide vanes and
first two rows of stators Annular SoLoNox combustor with 12 lean premix fuel
injectors. Three-stage turbine assembly, Turbine exhaust collector.
The components of the Taurus 60 engine are maintained in accurate alignment by
mating flanges with pilot surfaces and are bolted together to form a rigid
assembly. The speed-reducing gearbox is driven by the compressor rotor shaft.
Accessory pads drive the main lube oil pump and other accessories, depending on
the application, and support the starter motor. The gas turbine
output shaft is mechanically connected to both the compressor and turbine
sections of the engine to form a "solidor "singleshaft configuration.
This feature enhances speed stability and response under constant and varying
load conditions -- a highly desirable feature in generator applications
requiring precise frequency control.
SPEED REDUCING GEARBOX
The speed-reducing gearbox is an industrial design manufactured by Solar
specifically for the Taurus 60 IPG generator set. The gearbox mounts directly on
the Taurus 60 gas turbine to reduce engine speed to 1800 rpm (60 Hz).
GENERATOR
Generator Rating. Generator nameplate rating per NEMA standards is 6,625 Kva at
0.8 power factor (5,300kw) 13,800 volts at 104°F (40°C), 3281 ft (1000 m)
elevation for continuous duty. The generator is rated so that the generator will
not limit turbine performance over the range of site ambient temperatures.
- Generator Standard Features
- Sleeve Bearings with pressure fed sumps
- Six-lead WYE connection
- Terminal box
- Form wound stator windings
- Damper windings
- Rotor balance to 125% rated speed
- Permanent magnet pilot exciter
- Anti-condensation space heaters
- 300% short circuit capability for 10 seconds
- Overload capacity per NEMA:
- 150% rated current for 1 minute (b) 110% for 2 hours
- Voltage Regulator Characteristics
- Solid state
- Single-phase sensing
- ±10% voltage adjustment range
- 0.5% steady state voltage regulation
- Reactive load sharing to within 5% nameplate rating
- Crosscurrent compensation capability
- Wave Form Characteristics
Deviation Factor [maximum]
Harmonic Content [maximum]
Telephone Interference Factor
Balanced Residual
Voltage Drift. The change in voltage will not exceed 1.0% over a
30-minute period when the generator is operating at rated voltage and 0.8 to 1.0
power factor and with a constant load between no load and full rated load.
Generator Voltage. The generator output is 13,800 Volt, 3 phase, 60 Hz.
Insulation conforms to NEMA class F.
TURBINE START SYSTEM
A direct drive AC motor is provided to start the Taurus 60 engine. A variable
frequency drive [VFD] motor controller is included for installation in the motor
control center [MCC]. 3 phase AC power is required at 460VAC, 60Hz, 250 Amperes.
The control system provides all required sequencing to quickly and reliably
start the turbine.
FUEL SYSTEM
The fuel system, in conjunction with the electrical control system, includes all
necessary components to control the fuel pressure, to schedule fuel flow during
start-up, and to modulate fuel flow during operation.
Natural Gas Fuel. A natural gas fuel system is provided with all components
necessary to maintain turbine speed to provide a constant generator output
frequency and/or load depending on the generator set mode of operation. Solar's
Specification ES 9-98 contains the specific fuel requirements.
The natural gas fuel system includes: Primary fuel shutoff valve, Pilot-operated
secondary fuel shutoff valve
Electronic fuel actuator
10-micron pilot gas filter
2 fuel injector assemblies
Valve check pressure switch
High gas fuel pressure shutdown switch
Gas strainer System requirements for the natural gas fuel are as follows:
Requires a constant supply of gas at a maximum flow demand rate of 32.2 nm3/min
(1200 scfm) at 1725-kpa-gauge (225 psig) minimum pressure. Gas fuel pressure is
used to operate the fuel system pilot valve.
The gas fuel should be free of sulfur, contaminants, entrained water, and liquid
hydrocarbons
Gas fuel must conform to Solar's Specification ES 9-98
LUBE OIL SYSTEM
A complete lube oil system suitable for operation with lube oil conforming to
Solar's Specification ES 9-224 is included. The lube oil system provides oil to
the bearings in the Taurus 60 gas turbine engine, gearbox and generator.
Instrumentation, flow control and on frame piping are included.
Main Lube Oil Pump. An engine driven lube oil pump is provided with suction
strainer. Post Lube Backup Pump. A 1.5hp (1.1 kW) AC motor driven pump is
provided to supply post operation lube oil flow in the event of power failure.
Power is provided by a 24 VDC battery system through a VFD/ inverter.
Drain Line Sight Glasses. Sight glasses are provided on the drain lines from all
gas turbine, generator and gearbox bearings. Note that some of the gas turbine
bearings have a common drain line.
Lube Oil Tank. A 420-gallon operating capacity carbon steel lube oil tank is
provided. The lube oil tank is integral with the package frame. Lube oil level
indicator, fill connection with inlet strainer and drain connections are
included.
Lube Oil Tank Heater. A thermostatically controlled 4.5 kW lube oil tank heater
is provided. Electric power requirements are 460 V, 60 Hz, three phase.
Lube Oil Vent Separator. An off skid mechanical coalescer element is provided to
remove oil vapor from the lube oil tank vent. Recovered oil drains back to the
lube oil tank. Interconnect piping between the frame flanges and the vent
separator is not included in Solar's scope. The vent separator is nominally
rated for less than 0.2 gallons/day (0.76 L/day) oil loss.
Lube Oil Cooler. An air/oil lube oil cooler is provided. The fan is driven by a
3.7 kW AC motor. The lube oil cooler is designed for off skid installation.
Interconnect piping between the frame flanges and the lube oil cooler is
included according to current design.
Lube Oil Type. Lube oil is not included. The lube oil supplied must be
consistent with the requirements of Solar specification ES 9-224.
Lube Oil Filter. Single 5-micron oil filter units are provided with drain, fill
and vent valves.
CONTROL SYSTEM
Solar Control System.
The Turbotronic control system is provided and is a highly integrated
programmable logic controller [PLC] based control system. The control system is
installed on the package frame to minimize interconnect wiring.
The control system includes a microprocessor, remote communications modules;
chassis based and flex input/output modules, line synchronization module, power
supplies and a hardware backup shutdown system.
The control system provides for control of all phases of package operation to
include start and shutdown sequencing, normal operation, and malfunction
shutdown.
Vibration Monitoring. Vibration monitoring is provided to include three
proximity probes, one per bearing, on the Taurus 60 engine. One accelerometer is
provided with the gearbox. Two velocity transducers, one per bearing is provided
with the generator. Preset warning indications and malfunction shutdown
initiation are provided.
Temperature Monitoring. Temperature monitoring is provided to include the Taurus
60 engine thrust bearing, lube oil drains, and lube oil header and the generator
bearings and stator windings. Preset warning indications and malfunction
shutdown initiation are provided. Ambient, lube oil tank and enclosure
temperatures are also monitored.
Audible Alarm. An audible alarm horn is provided to sound whenever the unit has
an alarm or shutdown condition. A horn silence push button is mounted on the
face of the control panel.
Local Display. The control system is installed on the package frame in
weatherproof enclosures. A digital control panel [DCP] with all of the necessary
switches and indicators is provided. In addition to display of "first
outmalfunctions, the DCP can display:
System summary/normal running data o System status
Digital display of engine and generator parameters
Alarms and Shutdowns
Engineering Units. Temperature data is displayed in °F. Pressure data is
displayed in pounds per square inch [psi].
Language. Package labels and screen displays are in English.
Supervisory Interface. An RS 232C/422-interface module is provided to give the
user's supervisory computer access to the Turbotronic control system data.
Limited control capability is provided to allow the supervisory computer to
start and stop the unit, reset alarms, and raise/lower speed and load set
points. The communications protocol is Allen
Bradley's DF1. The interface module may be located up to 10,000 feet (3,048
meters) from the turbine control system and located up to 50 feet (15 meters)
from the supervisory computer for the RS 232C module or 4,000 feet (1,219
meters) for the RS 422 module. The modules are "table topunits and require
120 Vac, 50/60 Hz power.
GENERATOR CONTROL AND MONITORING
Integrated monitoring and control of the generator is provided using a specially
designed module in the PLC to receive input data from potential and current
transformers. The system calculates real and reactive power, power factor and
the variables required for synchronization.
Automatic Synchronizing. An automatic synchronizer is provided with the control
system to automatically synchronize the unit to the bus through push-button
control on the digital control panel [DCP] or by receipt of an appropriate
remote signal. A synch check relay is provided as an additional permissive and
for backup protection.
Motorized Voltage Adjust. Raise/lower voltage push button control is provided on
the digital control panel to control a motorized potentiometer for voltage
control. An additional raise/lower switch, supplied by others, may be used to
control voltage from a remote location.
KW Controller. A kW import controller is provided to control the real load (kW)
on the generator set while operating in parallel with a utility or other large
source. The kW controller monitors the load imported from the utility source and
adjusts the generator set fuel flow to maintain a pre-set level of imported
power on the utility at all times. This control mode is for applications where
it is desired to prevent any power from being exported to the utility.
Protection against excessive kW load while in parallel with a large source is
provided by the control system "T5temperature limiter. The kilowatt load
level select switch and adjustment is located on the digital control panel.
KVAR/Power Factor Controller. A kvar/power factor controller is provided to
maintain a constant reactive load (WAR) output or constant power factor (pf) on
the generator set while the unit is operating in parallel with a utility or
other large source. The controller applies a signal directly to the voltage
regulator adjust circuit to maintain a constant reactive load or power factor
with changes in the infinite bus voltage level. The system incorporates a set
point adjust rheostat to set the desired WAR or pf, a selector switch to choose
WAR or pf control mode, and a switch to turn the controller on and off
ADDITIONAL ANCILLARY EQUIPMENT
The following additional ancillary equipment is also provided for the
turbine-generating package:
(a) Neutral Ground Resistor
(b) Auxiliary Load Transformer (13.8 kv:480 V, 60 Hz). This transformer
eliminates the requirement for an alternate 480VAC shore power supply.
(c) (C) Liquid Fuel Boost Pump (with dual fuel option)
(d) XI. DRAWINGS
(e) One set of standard drawings is provided with each turbo machinery package.
(f) XII. OPERATION AND MAINTENANCE MANUALS
(g) One set of operation and maintenance manuals are provided with each turbo
machinery package.
SECTION 3
POWER CONTROL ROOM (PCR) BUILDING FOR A SOLAR TAURUS 60 POWER GENERATOR SET:
Utility Grade 15KV class metal clad paralleling switchgear:
The Power Control Room Building contains the following equipment:
PCR HVAC system
Generator Main Circuit Breaker 15KV
Auxiliary Transformer Feeder Circuit Breaker
Bus pts, Feeder cts, Metering cts and pts, and Protective Relay Module
Lightning Arrestor and Surge Capacitor
Motor Control Center (Serves Turbine Generator 480VAC Auxiliary Loads)
120VDC Turbine Generator Battery System with Charger
Dedicated 120VDC Switchgear Battery System with Charger
Note:
The above description is a general outline configuration of a Solar T-60 mobile
package as built by Solar. The offered equipment may have further options as was
ordered by seller when the equipment was built. Final "as built" build
of material is subject to verification but will meet or exceed the above
description.