The Utility Warehouse

Maine Yankee is Selling the Following Equipment
Contact Mr. Lewis R. Loon
 207-882-4515  fax 207-882-5353  Email: loonlewi@myapc.com
 Maine Yankee Home Page (click here)
 

Motor Control Center 

Westinghouse Type W  480-120 vac  60hz 3ph   MCC-12D containing 18 buckets, 5 section

Buckets

Height

Description

4

12

Non-reversing motor starter, size 1

2

12

Each bucket contains two breakers

1

12

Non-reversing motor starter, size 2

2

12

Non-reversing motor starter, size 1, with lights

5

18

Reversing motor starter, size 1

2

18

Non-reversing motor starter, size 2

1

18

Non-reversing motor starter, size 2

1

24

MCC main breaker

Westinghouse Type W  480-120 vac  60hz 3ph   MCC-11D containing 18 buckets, 5 section

Buckets

Height

Description

6

12

Non-reversing motor starter, size 1

2

12

Reversing motor starter, size 1

1

12

Bucket contains two breakers

3

18

Reversing motor starter, size 1

3

18

Non-reversing motor starter, size 3

1

18

bucket contains one breaker

2

24

Bucket contains main breaker

Westinghouse Type W  480-120 vac  60hz 3ph   MCC-8A East containing 17 buckets, 5 section

Buckets

Height

Description

2

12

Each bucket contains 1 breaker

1

12

Bucket contains 2 breakers

1

12

Non-reversing motor starter, size 1

1

12

Non-reversing motor starter, size 1, with lights

11

18

Reversing motor starter, size 1

1

18

Reversing motor starter, size 1 (MISSING BREAKER) on & off switch

Westinghouse Type W  480-120 vac  60hz 3ph   MCC-8A West containing 12 buckets, 5 section

Buckets

Height

Description

3

12

Non-reversing motor starter, size 1

2

12

Non-reversing motor starter, size 2

1

12

Bucket contains 2 breakers

1

18

Non-reversing motor starter, size 1

1

18

Reversing motor starter, size 1

1

18

Non-reversing motor starter, size 3

1

18

Non-reversing motor starter, size 1, (MISSING BREAKER)

1

24

Bucket contains 1 breaker

1

24

Bucket contains main breaker

Westinghouse Type W  480-120 vac  60hz 3ph   MCC-10B South containing 7 buckets, 2 section

Buckets

Height

Description

4

12

Non-reversing motor starter, size 1

2

12

Each bucket contains 2 breakers

1

18

Bucket contains main breaker

Westinghouse Type W  480-120 vac  60hz 3ph   MCC-10B North containing 7 buckets, 2 section

Buckets

Height

Description

3

12

Non-reversing motor starter, size 1

1

12

Non-reversing motor starter, size 2, with lights

2

12

Each bucket contains 2 breakers

1

18

Bucket contains 1 breaker

Motor Control Center 

Westinghouse Type W  480-120 vac  60hz 3ph   MCC-7A East containing 20 buckets, 5 section

Buckets

Height

Description

4

12

Each bucket contains 2 breakers

1

12

Non-reversing motor starter, size 1

1

18

Bucket contains one breaker

1

18

Reversing motor starter, size 1, on off switch

12

18

Reversing motor starter, size 1

1

24

Bucket contains main breaker

Westinghouse Type W  480-120 vac  60hz 3ph   MCC-7A West containing 11 buckets, 5 section

Buckets

Height

Description

2

12

Non-reversing motor starter, size 1

1

12

Non-reversing motor starter, size 1, with lights

1

18

Reversing motor starter, size 1

1

18

Reversing motor starter, size 1, (BREAKER MISSING), on & off switch

2

18

Non-reversing motor starter, size 3, (BREAKER MISSING)

3

18

Non-reversing motor starter, size 3

1

24

Buckeet containes main breaker

Westinghouse Type W  480-120 vac  60hz 3ph   MCC-14B containing 26 buckets, 6 section

Buckets

Height

Description

18

12

Non-reversing motor starter, size 1

4

12

non-reversing motor starter, size 2

2

12

Each bucket contains 1 breaker

1

12

Bucket contains 2 breakers

1

12

Non-reversing motor starter, size 1, (BREAKER MISSING)

Westinghouse Type W  480-120 vac  60hz 3ph   MCC-13A East containing 11 buckets, 3 section

Buckets

Height

Description

5

12

Non-reversing motor starter, size 1

1

12

Non-reversing motor starter, size 2

1

12

Non-reversing motor starter, size 2,  lights

2

12

Each bucket contains 2 breakers

1

18

Non-reversing motor starter, size 3, lights

1

24

Bucket contains main breaker

Westinghouse Type W  480-120 vac  60hz 3ph   MCC-13A West containing 9 buckets, 3 section

Buckets

Height

Description

3

12

Each bucket contains 2 breakers

1

12

Bucket contains 1 breaker

2

18

Non-reversing motor starter, size3

1

18

Non-reversing motor starter, size 2

1

18

Bucket contains 1 breaker

1

24

Bucket contains main breaker

Westinghouse Type W  480-120 vac  60hz 3ph   MCC-12C South containing 5 buckets, 2 section

Buckets

Height

Description

2

12

Non-reversing motor starter, size 1

1

12

Non-reversing motor starter, size 2

1

12

Bucket contains 2 breakers

1

18

Bucket contains main breaker

Motor Control Center 

Westinghouse Type W  480-120 vac  60hz 3ph   MCC-12C North  containing 8 buckets, 2 section

Buckets

Height

Description

2

12

Non-reversing motor starter, size 1, lights

4

12

Each bucket contains 2 breakers

1

18

Bucket contains 1 breaker

2

24

Buckets contains main breakers

Motor Control Center  5 STAR 

Westinghouse Type 5 Star 480-120 vac  60hz 3ph   MCC-12E  containing 9 buckets, 2 section

Buckets

Height

Description

5

12

Non-reversing motor starter, size 1

2

12

Non-reversing motor starter, size 2

1

12

Bucket contains 2 breakers

1

18

Reversing motor starter, size 2

Westinghouse Type 5 Star 480-120 vac  60hz 3ph   MCC-98I  containing 10 buckets, 4 section

Buckets

Height

Description

3

12

Each bucket contains 2 breakers

2

12

Non-reversing motor starter, size 1

3

18

Reversing motor starter, size 1

1

18

Non-reversing motor starter, size 4

1

24

Bucket contains main breaker

These MCC'S are used, they were in working condition when plant was shut down. There appearance is very good.

The exception is MCC-11D and MCC-12D these two MCC'S were in a pump house and there are very minor rust spots on

the cabinet, with some on the buckets.


Main Entrance

Email: sales@rmaglobal.com   Phone: (503) 239-5157   Fax: (503) 239-5136   Copyright 1995-2002: RMA Inc.